Cassette Type HVAC Systems Central Air Conditioner Ceiling 4-Ways 2 Pipe 4 Pipe Cassette Fan Coil Unit for Factory

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 3years
Still deciding? Get samples of US$ 215/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
76
Year of Establishment
2013-08-22
  • Cassette Type HVAC Systems Central Air Conditioner Ceiling 4-Ways 2 Pipe 4 Pipe Cassette Fan Coil Unit for Factory
  • Cassette Type HVAC Systems Central Air Conditioner Ceiling 4-Ways 2 Pipe 4 Pipe Cassette Fan Coil Unit for Factory
  • Cassette Type HVAC Systems Central Air Conditioner Ceiling 4-Ways 2 Pipe 4 Pipe Cassette Fan Coil Unit for Factory
  • Cassette Type HVAC Systems Central Air Conditioner Ceiling 4-Ways 2 Pipe 4 Pipe Cassette Fan Coil Unit for Factory
  • Cassette Type HVAC Systems Central Air Conditioner Ceiling 4-Ways 2 Pipe 4 Pipe Cassette Fan Coil Unit for Factory
  • Cassette Type HVAC Systems Central Air Conditioner Ceiling 4-Ways 2 Pipe 4 Pipe Cassette Fan Coil Unit for Factory
Find Similar Products

Basic Info.

Model NO.
FP-34, FP-51, FP-68, FP-85, FP-102, FP-136, FP-170
Type
Fan Coil Unit
Air Tube Material
Galvanized Sheet
Corrosion Durability
Ultrahigh
Operating Voltage
220V
Noise Level
Ultra Low
Application Fields
Hotel
Mounting
Ceiling Mount
Lifetime
10~15 years
Certification
RoHS, UR, ISO, CE, CCC
Condition
New
Transport Package
Plastic Foam, Plastic Bag, Carton, Pallat or Wood
Specification
800*800*300
Trademark
YESNCER
Origin
China
Production Capacity
150000

Product Description

Category Fan Coil UnitTags cooling, fan coil unit, heating

It can cooling and heating in the winter and summer

Cooling Capacity from 1.98kw-12.6kw

Cooling Capacity

1.98kw, 10.8kw, 12.6kw, 2.98kw, 3.68kw, 4.98kw, 5.58kw, 7.2kw, 9.9kw

Heating Capacity

2.98kw-18.9kw

Noise

34dB(A)-52dB(A)

Power

34w-198w

Voltage

220V-240V/50Hz

ASK FOR A QUOTE
 

Product Video






 

YESNCER, since 1986.

YESNCER is a fan coil unit manufacturer in China, established in 1986.
Engaged in the fan coil industry, production, research and development, and manufacture of horizontal concealed fan coils that have been produced.
Provide OEM&ODM service.
Tell me your needs, I can solve your problems.

 

Application

A cassette-type fan coil unit is a kind of equipment installed at the end of an air conditioner, which is widely used in our work and life. In our big family of fan coils, 4-way cassette fan coil is a very good type of fan coil. 4-way cassette fan coil unit is exquisitely structured, compact, durable, beautiful in appearance, noble and elegant, and is embedded with ultra-thin fuselage in large shopping malls and office buildings.

360-degree uniform air outlet without a crash, with water as the medium to exchange cold and hot, which fully saves energy and protects the environment. The unique adjustment switch with three gears can select different comfortableness for different people so that everyone can feel the charm of the air conditioner and enjoy the temperature.

Cassette Type HVAC Systems Central Air Conditioner Ceiling 4-Ways 2 Pipe 4 Pipe Cassette Fan Coil Unit for Factory
Cassette Type HVAC Systems Central Air Conditioner Ceiling 4-Ways 2 Pipe 4 Pipe Cassette Fan Coil Unit for FactoryCassette Type HVAC Systems Central Air Conditioner Ceiling 4-Ways 2 Pipe 4 Pipe Cassette Fan Coil Unit for FactoryCassette Type HVAC Systems Central Air Conditioner Ceiling 4-Ways 2 Pipe 4 Pipe Cassette Fan Coil Unit for FactoryCassette Type HVAC Systems Central Air Conditioner Ceiling 4-Ways 2 Pipe 4 Pipe Cassette Fan Coil Unit for FactoryCassette Type HVAC Systems Central Air Conditioner Ceiling 4-Ways 2 Pipe 4 Pipe Cassette Fan Coil Unit for FactoryCassette Type HVAC Systems Central Air Conditioner Ceiling 4-Ways 2 Pipe 4 Pipe Cassette Fan Coil Unit for Factory

Working principle:

The function of concealed fan coil is to cool or heat indoor air or outdoor mixed air through the surface cooler and then send it into the room so that the indoor air temperature can be lowered or raised to meet people's comfort requirements. Cold (hot) medium water in the coil pipe is supplied centrally by the machine room.

Product Details

 

 

 

 

Equipped with a drainage pump. The advanced 4-way cassette Fan coil is equipped with a condensed water drainage pump, which is flexible in design and can easily remove condensed water.

 

 

Cassette Type HVAC Systems Central Air Conditioner Ceiling 4-Ways 2 Pipe 4 Pipe Cassette Fan Coil Unit for FactoryCassette Type HVAC Systems Central Air Conditioner Ceiling 4-Ways 2 Pipe 4 Pipe Cassette Fan Coil Unit for FactoryCassette Type HVAC Systems Central Air Conditioner Ceiling 4-Ways 2 Pipe 4 Pipe Cassette Fan Coil Unit for Factory

 

 

Fan: ceiling cassette fan coil unit the three-dimensional spiral blades ensure the air volume and thinner shape, and the irregular blade pitch greatly reduces the running noise

 

 

 

 

 

 

 

The condenser and the round condenser increase the heat dissipation area, and the heat dissipation is more evenly combined with multiple water inlet and outlet heads, which can accelerate the heat exchange speed and improve the heat exchange efficiency.

 

 

Cassette Type HVAC Systems Central Air Conditioner Ceiling 4-Ways 2 Pipe 4 Pipe Cassette Fan Coil Unit for FactoryCassette Type HVAC Systems Central Air Conditioner Ceiling 4-Ways 2 Pipe 4 Pipe Cassette Fan Coil Unit for FactoryCassette Type HVAC Systems Central Air Conditioner Ceiling 4-Ways 2 Pipe 4 Pipe Cassette Fan Coil Unit for FactoryCassette Type HVAC Systems Central Air Conditioner Ceiling 4-Ways 2 Pipe 4 Pipe Cassette Fan Coil Unit for FactoryCassette Type HVAC Systems Central Air Conditioner Ceiling 4-Ways 2 Pipe 4 Pipe Cassette Fan Coil Unit for FactoryCassette Type HVAC Systems Central Air Conditioner Ceiling 4-Ways 2 Pipe 4 Pipe Cassette Fan Coil Unit for FactoryCassette Type HVAC Systems Central Air Conditioner Ceiling 4-Ways 2 Pipe 4 Pipe Cassette Fan Coil Unit for Factory

 

 

 

 

The air inlet filter is fixed by snap, which is convenient to disassemble and clean the filter screen.

 

 

 

 

Motor, the motor is a general motor with stable performance. The installation position of the motor is increased in density and thickened in rubber to

reduce the noise and resonance generated by the motor during operation.

 

 

 

 

Technical Data OF Cassette Fan Coil Unit

Technical Data of 2 Pipe Fan Coil Unit
Model and performance   FP34 FP51 FP68 FP85 FP102 FP136 FP170 FP204 FP238
Rated air flow
m3/h
high 340 510 680 850 1020 1360 1700 2040 2380
Medium 280 390 520 640 790 1030 1290 1500 1800
low 180 260 350 430 520 690 860 1030 1200
Rated cooling capacity
W
high 1980 2980 3680 4980 5580 7200 9900 10800 12600
Medium 1631 2279 2814 3750 4322 5534 7512 8088 9681
low 1048 1519 1894 2519 2854 5534 5008 5554 6454
Rated heating
capacity
W
high 2980 4800 5480 7200 8180 10800 14500 16200 18900
Medium 2454 3671 4191 5421 6335 8179 11005 12353 14521
low 1578 2447 2821 3600 4481 5479 7335 8482 9681
The input power W 34 50 58 72 92 126 128 152 198
The amount of water
m3/h
0.42 0.52 0.62 0.86 0.98 1.08 1.58 1.78 1.92
Water press loss
Kpa
14 14 16 18 22 25 39 44 46
Motor number 1
power 220V~240/50HZ  
Technical Data of 4 Pipe Cassette Fan Coil Unit
Model and performance   FP34 FP51 FP68 FP85 FP102 FP136 FP170 FP204 FP238
Rated air flow
m3/h
high 360 520 650 840 1000 1320 1660 1950 2090
Medium 290 420 510 670 800 1050 1330 1560 1670
low 220 310 390 500 600 790 1000 1170 1250
Rated cooling capacity
W
high 1980 2980 3680 4980 5580 7200 9900 10800 12600
Medium 1631 2279 2814 3750 4322 5534 7512 8088 9681
low 1048 1519 1894 2519 2854 5534 5008 5554 6454
Rated heating
capacity
W
high 1950 3000 3750 4850 5750 7400 9700 10900 11850
Medium 1700 2550 3200 4100 4850 6250 8200 9250 10050
low 1350 2000 2500 3250 3850 4950 6500 7300 7950
The input power W 34 50 58 72 92 126 128 152 198
The amount of water
m3/h
0.42 0.52 0.62 0.86 0.98 1.08 1.58 1.78 1.92
Water press loss
Kpa
14 14 16 18 22 25 39 44 46
Motor number 1
power 220V~240/50HZ  

Note:
1. The rated air volume refers to the outlet static pressure of 0Pa.
2. Cooling operation parameters: inlet air dry bulb temperature is 27ºC, humidity temperature is 19.5ºC, outlet water temperature is 7ºC, return water temperature is 12ºC.
3. Heating condition parameters: inlet air dry bulb temperature is 20ºC, inlet water temperature is 60ºC, outlet water temperature is 50ºC.

Drawing

 

 

 